Unit system used?
|
US Units
|
Number of specimens
|
6
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.18 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Cross sectional area of cylinder 3
|
28.18 in^2
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Cross sectional area of cylinder 4
|
28.09 in^2
|
Cross sectional area of cylinder 5
|
28.09 in^2
|
Cross sectional area of cylinder 6
|
28.09 in^2
|
Average diameter of cylinder 1
|
5.99 in
|
Average diameter of cylinder 2
|
6.00 in
|
Compressive strength of cylinder 1
|
3826.5 psi
|
Compressive strength of cylinder 2
|
3622.4 psi
|
Average diameter of cylinder 3
|
5.99 in
|
Compressive strength of cylinder 3
|
3819.9 psi
|
Compressive strength (to nearest 10 psi)
|
3810 psi
|
Average diameter of cylinder 4
|
5.98 in
|
Compressive strength of cylinder 4
|
3842.8 psi
|
Average diameter of cylinder 5
|
5.98 in
|
Compressive strength of cylinder 5
|
3901.4 psi
|
Average diameter of cylinder 6
|
5.98 in
|
Compressive strength of cylinder 6
|
3875.6 psi
|
Maximum load on cylinder 1
|
107830 lb
|
Maximum load on cylinder 2
|
102405 lb
|
Maximum load on cylinder 3
|
107645 lb
|
Maximum load on cylinder 4
|
107945 lb
|
Maximum load on cylinder 5
|
109590 lb
|
Maximum load on cylinder 6
|
108865 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
2
|
Type of fracture pattern of cylinder 4
|
2
|
Type of fracture pattern of cylinder 5
|
3
|
Type of fracture pattern of cylinder 6
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Correction factor for cylinder 5
|
1
|
Correction factor for cylinder 6
|
1
|
Age of specimen
|
7 days
|