Print Report | Back to Sample Detail

Sample Record for 2022-07-19-28

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993344 DEA: 022J3804 EFIS: 0221000072 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-3-R48.0/51.0
Work Description: HMA OVERLAY AND REPLACE AC SURFACING.
Location Description: SISKIYOU COUNTY IN AND NEAR YREKA FROM 0.1 MILE SOUTH OF JUNIPER DRIVE TO 0.3 MILE NORTH OF CALAMITY LANE
Contractor Name: Tullis, Inc
Contractor Address: P.O box 493416, Redding, CA 96001
Resident Engineer: Austin Henry Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-07-19-28
TL Number from the TL Form: 853092
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/19/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2022
The quantity of what the sample constitutes: 750 tons
A brief description of the sample: 1 box of Lime Treated 3/8-inch Type A HMA (eq. PG 64-28 M) with 24.0% RAP and virgin PG 58-34 M from Valero – Benecia
From where was the sample collected: Job Site
Laboratory sample identification: D79103
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis – Northstate Asphalt (Redding, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 3/8 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2022-07-19-28-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/01/2022
Date Tested: 07/21/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.92 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.67 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data