Print Report | Back to Sample Detail

Sample Record for 2022-07-01-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993535 DEA: 081M1104 EFIS: 0821000078 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-215-10.0/17.2
Work Description: HMA, COLD PLANE AC PAVEMENT, AND TRAFFIC STRIPE TAPE.
Location Description: SAN BERNARDINO COUNTY?FROM 0.1 MILE NORTH OF 27TH STREET TO 0.1 MILE SOUTH OF DEVORE ROAD
Contractor Name: CALMEX ENGINEERING INC.
Contractor Address: 2764 S VISTA AVE, BLOOMINGTON, CA 92316
Resident Engineer: VuThanh Nguyen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-07-01-38
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 07/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/11/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0440-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan San Bernardino Portable

Material Information

Performance Grade: PG 64-28 M
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2022-07-01-38-1
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 07/15/2022
Date Tested: 07/12/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Specific Gravity 0.952

Test 2 of 7

DIME Test ID: 2022-07-01-38-2
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/15/2022
Date Tested: 07/12/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? No
Mass of empty container #1 176.518 grams
Mass of empty container #2 169.581 grams
Mass of container #1 before test (m1i) 211.644 grams
Mass of container #2 before test (m2i) 204.671 grams
Mass of container #1 after test (m1f) 210.908 grams
Mass of container #2 after test (m2f) 203.931 grams
Average mass change -2.102 percent

Test 3 of 7

DIME Test ID: 2022-07-01-38-3
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/15/2022
Date Tested: 07/12/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Phase Angle (δ) (for the 10 cycles) 62.7 degree
Dynamic Shear, G*/sin(δ) 1.04 kPa
(G*) x sin(δ)= no data

Test 4 of 7

DIME Test ID: 2022-07-01-38-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/15/2022
Date Tested: 07/12/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: RTFO Aged DSR
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Plate Diameter 25 mm
Phase Angle (δ) (for the 10 cycles) 67.3 degree
Dynamic Shear, G*/sin(δ) 2.27 kPa

Test 5 of 7

DIME Test ID: 2022-07-01-38-5
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 07/15/2022
Date Tested: 07/12/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? Pa-s
Time of test 8:55 HH:MM
Test Temperature 135 C
Speed 50 rpm
Spindle size 21 in
Torque 70 %
Viscosity reading #1 (A) 0.706 Pa-s
Viscosity reading #2 (B) 0.705 Pa-s
Viscosity reading #3 (C) 0.701 Pa-s
Average viscosity 0.704 Pa-s

Test 6 of 7

DIME Test ID: 2022-07-01-38-6
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 07/15/2022
Date Tested: 07/12/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Was test performed on residue from distillation or evaporation? Distillation
Soluble, percent 99.5 %
Insoluble, percent 0.5 %

Test 7 of 7

DIME Test ID: 2022-07-01-38-7
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/15/2022
Date Tested: 07/13/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: RETEST -1.352=,006=-1.346
Test Result Compliance: does not comply
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? Yes
Mass of empty container #1 170.720 grams
Mass of empty container #2 172.526 grams
Mass of container #1 before test (m1i) 205.474 grams
Mass of container #2 before test (m2i) 207.508 grams
Mass of container #1 after test (m1f) 205.005 grams
Mass of container #2 after test (m2f) 207.034 grams
Average mass change -1.352 percent