Print Report | Back to Sample Detail

Sample Record for 2022-06-30-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-6.7/R25.1
Work Description: Remove concrete pavement and base, and place HMA and JPCP
Location Description: ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Contractor Name: Coffman Specialties
Contractor Address: 9685 Via Excelencia, San Diego, CA 92126
Resident Engineer: Elvira Lenart Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-06-30-12
TL Number from the TL Form: 57A
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/30/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2022
The quantity of what the sample constitutes: 6
A brief description of the sample: concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1012-57A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coffman Specialties, Inc

Material Information

The concrete mix design number: 1906-23
The truck number from where the sample was collected: 5
The batch plant ticket number from where the sample was collected: 87
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: I10 WB Sta 32000 LANE 3
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-06-30-12-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Cured in accordance with ASTM C511
Verified Date: 07/13/2022
Date Tested: 07/07/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.27 in^2
Cross sectional area of cylinder 3 28.37 in^2
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 4 28.09 in^2
Cross sectional area of cylinder 5 28.18 in^2
Cross sectional area of cylinder 6 28.27 in^2
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 6.00 in
Compressive strength of cylinder 1 722.9 psi
Compressive strength of cylinder 2 693.8 psi
Average diameter of cylinder 3 6.01 in
Compressive strength of cylinder 3 695.3 psi
Compressive strength (to nearest 10 psi) 700 psi
Average diameter of cylinder 4 5.98 in
Compressive strength of cylinder 4 694.4 psi
Average diameter of cylinder 5 5.99 in
Compressive strength of cylinder 5 690.4 psi
Average diameter of cylinder 6 6.00 in
Compressive strength of cylinder 6 683.1 psi
Maximum load on cylinder 1 20510 lb
Maximum load on cylinder 2 19615 lb
Maximum load on cylinder 3 19725 lb
Maximum load on cylinder 4 19505 lb
Maximum load on cylinder 5 19455 lb
Maximum load on cylinder 6 19310 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Type of fracture pattern of cylinder 4 1
Type of fracture pattern of cylinder 5 1
Type of fracture pattern of cylinder 6 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Correction factor for cylinder 5 1
Correction factor for cylinder 6 1
Age of specimen 7 days