Print Report | Back to Sample Detail

Sample Record for 2022-06-24-35

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214451 DEA: 07303704 EFIS: 0714000035 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-101-8.0/27.3
Work Description: REPLACE CONCRETE BARRIERS.
Location Description: THE CITY AND COUNTY OF LOS ANGELES FROM PILGRIMAGE OVERCROSSING TO VALLEY CIRCLE BOULEVARD OVERCROSSING
Contractor Name: OHL USA
Contractor Address: 1920 Main Street, Suite 310, Irvine, California 92614
Resident Engineer: Kevin Bui Structure Rep.: Kwangsuk Suh

Sample Information

DIME Sample ID: 2022-06-24-35
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 06/24/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/25/2022
The quantity of what the sample constitutes: 100 cu. yd.
A brief description of the sample: 6"X12" concrete cylinder
From where was the sample collected: Job Site
Laboratory sample identification: 22-1547
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: National Ready Mixed Concrete Company

Material Information

The concrete mix design number: S29000
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 498208
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Transit mixer chute at 10 cubic yards
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-06-24-35-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Verified Date: 07/02/2022
Date Tested: 07/01/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.37 in^2
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Compressive strength (to nearest 10 psi) 680 psi
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.01 in
Maximum load on cylinder 1 19321 lb
Maximum load on cylinder 2 18908 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days