Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993235 DEA: 051H4504 EFIS: 0516000075
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-154-R31.8/R32.1
Work Description: CONSTRUCT CIDH CONCRETE PILES AND STRUCTURAL CONCRETE BRIDGE.
Location Description: SANTA BARBARA COUNTY IN AND NEAR SANTA BARBARA FROM PRIMAVERA ROAD UNDERCROSSING TO LA COLINA ROAD UNDERCROSSING
Contractor Name: CA Rasmussen
Contractor Address: 28548 LIVINGSTON AVENUE, VALENICA CA 91355
Resident Engineer: Jeffery Finn Structure Rep.: Emiliano Berntsen
DIME Sample ID: 2022-06-08-43
TL Number from the TL Form:
Sample Submitted By Organization: RMA Group - Rancho Cucamonga
Sample Organization Contact: (909) 989-1751
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/08/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/10/2022
The quantity of what the sample constitutes: 21 CY
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CEMEX Santa Barbara
The concrete mix design number: 1610837
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 30283577
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-06-08-43-1
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 06/29/2022
Date Tested: 06/08/2022
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-06-08-43-2
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 06/29/2022
Date Tested: 06/08/2022
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-06-08-43-3
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 06/29/2022
Date Tested: 06/08/2022
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-06-08-43-4
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/29/2022
Date Tested: 06/13/2022
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
1
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Compressive strength of cylinder (to nearest 10 psi)
|
3090 psi
|
Maximum load on cylinder 1
|
87350 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Age of specimen
|
5 days
|
Age of specimen in hours
|
0 hours
|
DIME Test ID: 2022-06-08-43-5
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/29/2022
Date Tested: 06/15/2022
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
1
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Compressive strength of cylinder (to nearest 10 psi)
|
3750 psi
|
Maximum load on cylinder 1
|
106080 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
0 hours
|
DIME Test ID: 2022-06-08-43-6
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/29/2022
Date Tested: 06/17/2022
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
1
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.02 in
|
Compressive strength of cylinder (to nearest 10 psi)
|
3860 psi
|
Maximum load on cylinder 1
|
109730 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Age of specimen
|
9 days
|
Age of specimen in hours
|
0 hours
|