STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 042640U4 Cty SON Rte 101 PM 0.9/3.6

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Richard Duncan

Date Reported:

03/05/2015

Address:

TL Number:

203427

City:

Project Name: CONSTRUCT PETALUMA BLVD SOUTH INTERCHANGE, REPLACE PETALUMA RIVER BR

Prime Contractor: GHILOTTI - CC MYERS JV

Sample Taken Date:

02/26/2015

Mix Design:

na

Contractor: Unknown

Location: SONOMA COUNTY IN AND NEAR PETALUMA FROM GUNN DRIVE TO ROUTE 101/116 SEPARATION AND OVERHEAD

Structure unique identifier: Unknown

Structure name: Unknown

Location of Pour:


The following testing has been tested in accordance with:

ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenCross sectional area of cylinder (in^2)Average diameter of cylinder (in)Compressive strength of cylinder (psi)Maximum load on cylinder (lb)Type of fracture pattern of cylinder
128.376.014746.51346591
228.276.004785.71352911

DIME Test ID: 2015-02-26-1-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4770
Age of specimen: 7 days
Certified By: Larry McCrum



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing