Print Report | Back to Sample Detail

Sample Record for 2022-06-14-24

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993590 DEA: 101J2004 EFIS: 1018000147 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-26-8.0/17.8
Work Description: COLD PLANE AND HMA OVERLAY.
Location Description: SAN JOAQUIN COUNTY AT AND NEAR LINDEN AT VARIOUS LOCATIONS FROM 0.7 MILE EAST OF GOGNA ROAD TO 1.3 MILES WEST OF SHELLEY ROAD
Contractor Name: George Reed Inc.
Contractor Address: 140 Empire Ave, Modesto, CA 95354
Resident Engineer: Troy Scheiber Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-06-14-24
TL Number from the TL Form: 994760
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 06/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/20/2022
The quantity of what the sample constitutes: 1 Can
A brief description of the sample: 3/4" HMA-A for Paving, PG 64-28M
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: George Reed - Clements Plant

Material Information

Performance Grade: PG 64-28 M
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2022-06-14-24-1
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/06/2022
Date Tested: 06/28/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: ORIG
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.174 kPa
Phase Angle (δ) (for the 10 cycles) 76.2 degree
Complex Modulus (G*) (for the 10 measurements) 1.453 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 1.50 kPa

Test 2 of 5

DIME Test ID: 2022-06-14-24-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/06/2022
Date Tested: 06/28/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.466 kPa
Phase Angle (δ) (for the 10 cycles) 62.4 degree
Complex Modulus (G*) (for the 10 measurements) 4.658 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 5.26 kPa

Test 3 of 5

DIME Test ID: 2022-06-14-24-3
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/06/2022
Date Tested: 06/28/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: RTFO MOD
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue two specimens
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.466 kPa
Phase Angle (δ) (for the 10 cycles) 62.4 degree
Complex Modulus (G*) (for the 10 measurements) 4.658 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 5.26 kPa
Stress Amplitude 2 0.265 kPa
Phase Angle 2 (δ) (for the 10 cycles) 65.5 degree
Complex Modulus 2 (G*) (for the 10 measurements) 2.648 kPa
Test Temperature (Specimen 2) 70.0 C
Dynamic Shear 2, G*/sin(δ) 2.91 kPa
Delta at 2.2 kpa 66.4 degree

Test 4 of 5

DIME Test ID: 2022-06-14-24-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/06/2022
Date Tested: 06/30/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: pav
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 13.497 kPa
Phase Angle (δ) (for the 10 cycles) 41.5 degree
Complex Modulus (G*) (for the 10 measurements) 1349.764 kPa
Test Temperature (Specimen 1) 22.0 C
(G*) x sin(δ)= 894 kPa

Test 5 of 5

DIME Test ID: 2022-06-14-24-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 07/06/2022
Date Tested: 07/01/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s -18.0 C
Maximum test bath temperature at 240 s -18.0 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) 0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 0.0 mN
Deflection at time 0.0 s 0.000 µm
Load at time 0.5 s 0.0 mN
Deflection at time 0.5 s 0.000 µm
Load at 60.0 s 997.0 mN
Beam deflection 60.0 s 1.307 µm
Measured Stiffness Modulus 60.0 s 61.200 mPa
Estimated Stiffness Modulus 60.0 s 61.300 mPa
Difference between stiffness moduli 60.0 s 0.16 %
Estimated m-value 60.0 s 0.336