Print Report | Back to Sample Detail

Sample Record for 2022-06-07-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215346 DEA: 034F1714 EFIS: 0318000208 QA Service Level: 1
DIST-CO-RTE-PM: 03-YOL-16-27.5/28.3
Work Description: CONSTRUCT CURB RAMPS, CURB & GUTTER AND LIGHTING.
Location Description: YOLO COUNTY IN ESPARTO FROM 0.2 MILE EAST OF FREMONT STREET TO 0.2 MILE SOUTH OF PLAINFIELD STREET
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Rd, Livermore, CA 94550
Resident Engineer: Howard Giang Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-06-07-17
TL Number from the TL Form: 849830
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphaltic Emulsion
Sample Taken Date: 06/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/08/2022
The quantity of what the sample constitutes: 1 jug
A brief description of the sample: Tack Coat oil, 3/4" HMA-RAP-SP
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Woodland Plant

Material Information

Emulsion Grade: SS-1h
Lot Number:
Sub Lot:

Test Results

Test 1 of 1

DIME Test ID: 2022-06-07-17-1
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Verified Date: 06/09/2022
Date Tested: 06/09/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: SS-1h
Test Result Compliance: complies
Additional Comments When Verified:
How many beakers will be used to conduct the test? 2
Beaker 1 Residue 58.0 %
Beaker 2 Residue 59.6 %
Percentage of residue 59.0 %