Sample Record for 2022-06-03-8
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215212 DEA: 081F1434 EFIS: 0815000233
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-38.2/51.5
Work Description: INDIVIDUAL SLAB REPLACEMENT, REPLACE BASE & GRIND CONCRETE PAVEMENT.
Location Description: RIVERSIDE COUNTY IN CORONA AND EASTVALE FROM 0.5 MILE SOUTH OF ONTARIO AVENUE UNDERCROSSING TO ROUTE 60/15 SEPARATION
Contractor Name: Myers & Sons Construction
Contractor Address: 4600 Northgate Boulevard, Suite 100, Sacramento, CA 95834-1121
Resident Engineer: Ali Chinichian Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2022-06-03-8
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/03/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/08/2022
The quantity of what the sample constitutes: 4 Boxes HMA, 82.14 tons out
A brief description of the sample: 1/2" RHMA-G-SP 1.0% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0345G-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA Corona
Material Information
HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2022-06-03-8-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 06/13/2022. The corrected test ID is: 2022-06-03-8-2
Reason: retested
Test 2 of 2
DIME Test ID: 2022-06-03-8-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/13/2022
Date Tested: 06/09/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
The test was superseded from test ID: 2022-06-03-8-1
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
no data
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
7.01 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|