Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040A7104 Cty ALA Rte 880 PM 28.4/29.2 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Joy Cheung |
Date Reported: |
03/13/2015 |
|
Address: |
TL Number: |
194803 |
||
City: |
||||
Project Name: WIDEN ROADS, RECONSTRUCT RAMPS WITH HMA, REPLACE 2 CONC OVERCROSSINGS. |
||||
Prime Contractor: RGW Construction |
||||
Sample Taken Date: |
02/13/2015 |
Mix Design: |
na |
|
Contractor: Unknown |
Location : ALAMEDA COUNTY IN ALAMEDA AND OAKLAND FROM 0.2 MILE SOUTH OF 29TH AVENUE OVERCROSSING TO 0.3 MILE NORTH OF 23RD AVENUE OVERCROSSING. |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.46 | 6.02 | 4397.9 | 125165 | 1 |
2 | 28.46 | 6.02 | 4434.9 | 126217 | 1 |
DIME Test ID: 2015-02-13-2-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4420
Age of specimen: 14 days
Certified By: She Vang
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.37 | 6.01 | 5609.1 | 159129 | 1 |
2 | 28.27 | 6.00 | 5294.3 | 149670 | 1 |
DIME Test ID: 2015-02-13-2-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5450
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing