Print Report | Back to Sample Detail

Sample Record for 2022-05-14-22

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214573 DEA: 073096U4 EFIS: 0719000091 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R0.0/R9.7
Work Description: PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
Contractor Name: FLATIRON WEST INC
Contractor Address: 15335 FAIRFIELD RANCH ROAD, CHINO HILLS, CA 91709
Resident Engineer: Ridwan Salman Structure Rep.: Adriana Pimienta

Sample Information

DIME Sample ID: 2022-05-14-22
TL Number from the TL Form: 22-1164
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 05/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2022
The quantity of what the sample constitutes: 400
A brief description of the sample: 6"x12" LCBRS cylinder
From where was the sample collected: Job Site
Laboratory sample identification: 22-1164
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Flatiron Volumetric Trucks

Material Information

The concrete mix design number: FIW 0110-1
The truck number from where the sample was collected: 3
The batch plant ticket number from where the sample was collected: 3
Concrete batch plant: Flatiron Volumetric Truck
The fabricator/manufacturer designation for the sample: FIW 0110-1
A detailed description of where the material sample was collected: CHUTE FROM TRUCK
Where the material sample would have been placed if not sampled: Roadway WB 210
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-05-14-22-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/21/2022
Date Tested: 05/21/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.01 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 1440 psi
Maximum load on cylinder 1 40477 lb
Maximum load on cylinder 2 41218 lb
Compressive strength of cylinder 1 1431.8 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 1452.9 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours 0 hours