Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-05-02-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/02/2022
Date that the sample was received by the laboratory/organization performing the testing: 05/06/2022
The quantity of what the sample constitutes: 1500
A brief description of the sample: A325 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: nucor
Rocap Number(s):
Heat Number(s): 1000214449
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325
Bolt Length(s): 1.75"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: .625"
Bolt Mfg. Lot Number: 467816A
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2022-05-02-27-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Pitch Diameter
|
.579 in
|
Pitch Diameter 2nd
|
.579 in
|
DIME Test ID: 2022-05-02-27-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Pitch Diameter
|
.582 in
|
Pitch Diameter 2nd
|
.582 in
|
DIME Test ID: 2022-05-02-27-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Pitch Diameter
|
.570 in
|
Pitch Diameter 2nd
|
.570 in
|
DIME Test ID: 2022-05-02-27-4
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Pitch Diameter
|
.578 in
|
Pitch Diameter 2nd
|
.578 in
|
DIME Test ID: 2022-05-02-27-5
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Pitch Diameter
|
.579 in
|
Pitch Diameter 2nd
|
.579 in
|
DIME Test ID: 2022-05-02-27-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
2.22 mils
|
DIME Test ID: 2022-05-02-27-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
2.34 mils
|
DIME Test ID: 2022-05-02-27-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
2.15 mils
|
DIME Test ID: 2022-05-02-27-9
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
2.21 mils
|
DIME Test ID: 2022-05-02-27-10
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Measurement Average
|
2.19 mils
|
DIME Test ID: 2022-05-02-27-11
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
29.12
|
Spacing
|
Ok
|
DIME Test ID: 2022-05-02-27-12
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
29.7
|
Spacing
|
Ok
|
DIME Test ID: 2022-05-02-27-13
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/18/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
467816A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
.625 in
|
Bolt Length
|
1.75 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
27.3
|
Spacing
|
Ok
|