Sample Record for 2022-05-05-31
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214573 DEA: 073096U4 EFIS: 0719000091
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R0.0/R9.7
Work Description: PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
Contractor Name: FLATIRON WEST INC
Contractor Address: 15335 FAIRFIELD RANCH ROAD, CHINO HILLS, CA 91709
Resident Engineer: Ridwan Salman Structure Rep.: Adriana Pimienta
Sample Information
DIME Sample ID: 2022-05-05-31
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 05/05/2022
Date that the sample was received by the laboratory/organization performing the testing: 05/09/2022
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 21651-1
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 1.15"x4"x6"
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA
Test Results
Test 1 of 4
DIME Test ID: 2022-05-05-31-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 06/01/2022
Date Tested: 05/31/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
56
|
Reading #2
|
55
|
Reading #3
|
50
|
Reading #4
|
55
|
Reading #5
|
51
|
Mean
|
53.4
|
Test 2 of 4
DIME Test ID: 2022-05-05-31-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 06/01/2022
Date Tested: 05/31/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.095
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2932.38 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.095
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2810.77 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.09
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2833.63 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2833.6 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2022-05-05-31-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 06/01/2022
Date Tested: 05/31/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.086
|
Sample 1 Tear Strength
|
242
|
Sample 2 Median Thickness
|
0.089
|
Sample 2 Tear Strength
|
234.8
|
Sample 3 Median Thickness
|
0.089
|
Sample 3 Tear Strength
|
229
|
Median of the Tear Strength Values
|
234.8 lb/in
|
Test 4 of 4
DIME Test ID: 2022-05-05-31-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 06/01/2022
Date Tested: 06/01/2022
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: