Print Report | Back to Sample Detail

Sample Record for 2022-05-11-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993234 DEA: 051H0004 EFIS: 0516000011 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-68-1.1/L4.3
Work Description: PLACE HMA AND MODIFY SIGNAL AND LIGHTING SYSTEMS.
Location Description: MONTEREY COUNTY IN AND NEAR PACIFIC GROVE AND MONTEREY FROM FOREST AVENUE TO ROUTE 68/1 SEPARATION
Contractor Name: Graniterock Company
Contractor Address: 350 Technology Drive, Watsonville, CA 95076
Resident Engineer: Tyler Lavering Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-05-11-10
TL Number from the TL Form: 956416
Sample Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Sample Organization Contact: 831-818-0254
Type of Sample: Acceptance
Type of Material: Asphaltic Emulsion
Sample Taken Date: 05/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2022
The quantity of what the sample constitutes: 05/11/22
A brief description of the sample: SS-1H Tack Coat
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Northwest Oil - Stockton, CA

Material Information

Emulsion Grade: SS-1h
Lot Number:
Sub Lot:

Test Results

Test 1 of 1

DIME Test ID: 2022-05-11-10-1
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
How many beakers will be used to conduct the test? 2
Beaker 1 Residue 59.4 %
Beaker 2 Residue 59.8 %
Percentage of residue 60.0 %