Sample Record for 2014-10-15-7
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 7780 DEA: 112T1824 EFIS: 1100020051
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-4.7/5.6
Work Description: REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Tom Davis Structure Rep.: Anh Ma
Sample Information
DIME Sample ID: 2014-10-15-7
TL Number from the TL Form: Unknown
Sample Submitted By Organization: Vulcan Materials Company - San Diego
Sample Organization Contact: (619) 572-9564
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 10/15/2014
Date that the sample was received by the laboratory/organization performing the testing: 10/15/2014
The quantity of what the sample constitutes: 2 bags
A brief description of the sample: Portland Cement Concrete Aggregates
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: vulcan misson valley
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-37-0035::CHULA VISTA
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: conveyor belt
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size:
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 4
DIME Test ID: 2014-10-15-7-1
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 01/30/2015
Date Tested: 10/15/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
1 in. x No. 4 - Coarse Aggregate
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
99 %
|
Cumulative percent passing the 3/4 in. sieve
|
85 %
|
Cumulative percent passing the 1/2 in. sieve
|
48 %
|
Cumulative percent passing the 3/8 in. sieve
|
19 %
|
Cumulative percent passing the #4 sieve
|
4 %
|
Cumulative percent passing the #8 sieve
|
1 %
|
Test 2 of 4
DIME Test ID: 2014-10-15-7-2
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 01/30/2015
Date Tested: 10/15/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Which test procedure is being used
|
Method A
|
Percent of sample passing the #200 sieve (by mass)
|
0.46 %
|
Test 3 of 4
DIME Test ID: 2014-10-15-7-3
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 01/30/2015
Date Tested: 10/15/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
0.375 in x No. 8 - Coarse Aggregate
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 3/8 in. sieve
|
93 %
|
Cumulative percent passing the #4 sieve
|
24 %
|
Cumulative percent passing the #8 sieve
|
3 %
|
Test 4 of 4
DIME Test ID: 2014-10-15-7-4
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 01/30/2015
Date Tested: 10/15/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Which test procedure is being used
|
Method A
|
Percent of sample passing the #200 sieve (by mass)
|
0.73 %
|