Sample Record for 2022-05-06-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214988 DEA: 050L7214 EFIS: 0515000097
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-1-32.6
Work Description: REMOVE & CONSTRUCT CONCRETE BRIDGE, CONCRETE SLAB, BRIDGE RAIL & HMA.
Location Description: SAN LUIS OBISPO COUNTY IN MORRO BAY AT TORO CREEK BRIDGE
Contractor Name: Souza Engineering Contracting, Inc
Contractor Address: 4027 SANTA FE ROAD, SAN LUIS OBISPO CA 93401
Resident Engineer: Rick Silva Structure Rep.: Salvador Heredia
Sample Information
DIME Sample ID: 2022-05-06-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 05/06/2022
Date that the sample was received by the laboratory/organization performing the testing: 05/09/2022
The quantity of what the sample constitutes: 156 Headed Bars Lot 1-2
A brief description of the sample: #10 HRC 150 T-Headed bars
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HRC Fountain Valley
Material Information
Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 4114532
Head Manufacturer Lot Number(s): MM20103137
Rebar Size: #10
Headed Bar Model Name: HRC 150 T Heads
Size of Head: Full Size - 9x
Head Connection Type: Friction Weld
Head Shape: Circular
Rebar Manufacturer: CMC Steel Arizona
Head Manufacturer: HRC Fountain Valley
Head Fabricator: HRC Fountain Valley
Material Standard Code: ASTM A706
Headed Bar Unique ID:
Test Results
Test 1 of 6
DIME Test ID: 2022-05-06-3-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/11/2022
Date Tested: 05/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 1 | 1.27 | 116225 | 91516 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 2 of 6
DIME Test ID: 2022-05-06-3-2
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/11/2022
Date Tested: 05/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 1 | 1.27 | 116103 | 91420 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 3 of 6
DIME Test ID: 2022-05-06-3-3
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/11/2022
Date Tested: 05/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 1 | 1.27 | 116737 | 91919 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 4 of 6
DIME Test ID: 2022-05-06-3-4
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/11/2022
Date Tested: 05/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 2 | 1.27 | 116965 | 92099 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 5 of 6
DIME Test ID: 2022-05-06-3-5
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/11/2022
Date Tested: 05/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 2 | 1.27 | 117223 | 92302 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 6 of 6
DIME Test ID: 2022-05-06-3-6
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/11/2022
Date Tested: 05/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples
|
1
|
Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | 2 | 1.27 | 116691 | 91882 | Ok Necking | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|