DIST-CO-RTE-PM: 07-LA-60,60,164,210-Var
Work Description: STORM WATER MITIGATION
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS
Contractor Name: CHUMO CONSTRUCTION INC
Contractor Address: 14425 Joanbridge St, Baldwin Park, CA 91706
Resident Engineer: Sushilkumar Chaudhari Structure Rep.: Pratheep Piratheepan
DIME Sample ID: 2022-03-10-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 03/10/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/10/2022
The quantity of what the sample constitutes: na
A brief description of the sample: 6X12 cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: WB 210 Loc 11
The fabricator/manufacturer/facility name: na
The concrete mix design number: LCBSC270N31
The truck number from where the sample was collected: 1507
The batch plant ticket number from where the sample was collected: na
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: na
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-03-10-47-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/05/2022
Date Tested: 03/10/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.01 in
|
Average diameter of cylinder 2
|
6.01 in
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Compressive strength (to nearest 10 psi)
|
880 psi
|
Maximum load on cylinder 1
|
25138 lb
|
Maximum load on cylinder 2
|
24581 lb
|
Compressive strength of cylinder 1
|
886.1 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
866.4 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data0 hours
|