Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993398 DEA: 07319204 EFIS: 0716000020
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-91,105,110,405-Various
Work Description: COLD PLANE, AND PLACE RUBBERIZED HMA AND RUMBLE STRIPS.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS
Contractor Name: CALMEX ENGINEERING INC.
Contractor Address: 2764 S VISTA AVE, BLOOMINGTON, CA 92316
Resident Engineer: Ramon Robillos Structure Rep.: Unknown
DIME Sample ID: 2022-04-27-21
TL Number from the TL Form: 0427A1
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/27/2022
Date that the sample was received by the laboratory/organization performing the testing: 04/28/2022
The quantity of what the sample constitutes: 800 tons
A brief description of the sample: 1/2" RWMA-G 108836 AAA-Irvine
From where was the sample collected: Manufacturer
Laboratory sample identification: 22-0110
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Irvine
DIME Test ID: 2022-04-27-21-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
Data has not been verified.
DIME Test ID: 2022-04-27-21-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/02/2022
Date Tested: 04/29/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
no data
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
Mass of HMA Sample prior to ignition
|
1545.7 g
|
Corrected Asphalt Binder Content
|
7.23 %
|
Mass Loss
|
no data
|
Mass of aggregate remaining after ignition
|
1431.7 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.15 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000.4 F
|