Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-03-21-56
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 03/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/21/2022
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Silica Fume
From where was the sample collected: Source
Laboratory sample identification: CM225213
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RED Mississippi
Brand: RED Industrial Products
Mill: Mississippi Silicon
Type of Cementitious Material: Silica Fume
DIME Test ID: 2022-03-21-56-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 06/21/2022
Date Tested: 06/14/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 1 mL of Glenium 3400 used for flow
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
yes
|
Age of specimen
|
7 days
|
The amount of flow
|
114 %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
5361 psi
|
Compressive strength of 2nd specimen
|
5381 psi
|
Compressive strength of 3rd specimen
|
5343 psi
|
Average Compressive strength (to nearest 10 psi)
|
5360 psi
|
Average Compressive strength (to nearest 10 psi) control group
|
4760 psi
|
Strength Activity Index of Portland Cement per ASTM C109
|
113 %
|
DIME Test ID: 2022-03-21-56-3
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 06/21/2022
Date Tested: 04/28/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Correction Factor (CF)
|
.29
|
Corrected Residue (Rc)
|
2.5
|