Print Report | Back to Sample Detail

Sample Record for 2022-04-13-28

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215697 DEA: 07318204 EFIS: 0715000286 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-Route 1-4.0/4.2
Work Description: CM/GC Project - Work consists of constructing secant wall and slope restoration
Location Description: near Point Mugu State Park 0.4 mile South of Sycamore Canyon Road.
Contractor Name: Flatiron/Drill Tech, a Joint Venture
Contractor Address: 15335 Fairfield Ranch Rd, Chino Hills, CA 91709
Resident Engineer: Saeid Shakeri Structure Rep.: Azizollah Maghsoudloo

Sample Information

DIME Sample ID: 2022-04-13-28
TL Number from the TL Form: 116156
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/13/2022
Date that the sample was received by the laboratory/organization performing the testing: 04/18/2022
The quantity of what the sample constitutes: 6
A brief description of the sample: Concrete Cylinder
From where was the sample collected: Job Site
Laboratory sample identification: 1039-56
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: na

Material Information

The concrete mix design number: Not Provided
The truck number from where the sample was collected: Not Provided
The batch plant ticket number from where the sample was collected: Not Provided
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Site
Where the material sample would have been placed if not sampled: secant wall 1 Primary Pile 13
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2022-04-13-28-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/24/2022
Date Tested: 04/27/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.02 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.69 in^2
Compressive strength (to nearest 10 psi) 5660 psi
Maximum load on cylinder 1 72860 lb
Maximum load on cylinder 2 70750 lb
Compressive strength of cylinder 1 5741.5 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 5575.3 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Age of specimen 14 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Test 2 of 3

DIME Test ID: 2022-04-13-28-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/24/2022
Date Tested: 05/11/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Compressive strength (to nearest 10 psi) 6220 psi
Maximum load on cylinder 1 78730 lb
Maximum load on cylinder 2 78390 lb
Compressive strength of cylinder 1 6233.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 6206.7 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Age of specimen 28 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Test 3 of 3

DIME Test ID: 2022-04-13-28-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/31/2022
Date Tested: 05/25/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.01 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.63 in^2
Compressive strength (to nearest 10 psi) 6740 psi
Maximum load on cylinder 1 86230 lb
Maximum load on cylinder 2 83620 lb
Compressive strength of cylinder 1 6860.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 6620.7 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Age of specimen 0 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data