Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042640F4 Cty SON Rte PM Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Gina Choi |
Date Reported: |
05/09/2022 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: |
||||
Prime Contractor: GHILOTTI CONSTRUCTION CO. INC. |
||||
Sample Taken Date: |
04/09/2022 |
Mix Design: |
4201A |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: 20-E0101 |
||||
Structure name: RW3 Wall |
||||
Location of Pour: RW3 Wall |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 77956 | 6142.0 | 1 |
2 | 4.03 | 12.76 | 72614 | 5693.0 | 1 |
3 | 4.03 | 12.76 | 77413 | 6069 | 1 |
DIME Test ID: 2022-04-09-15-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5970
Age of specimen: 30 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing