Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-04-06-2
TL Number from the TL Form:
Sample Submitted By Organization: QFC Inductries
Sample Organization Contact: (469) 646-0379
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/06/2022
Date that the sample was received by the laboratory/organization performing the testing: 04/11/2022
The quantity of what the sample constitutes: 136
A brief description of the sample: 1 1/2 x 4 1/4
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: formed fastener
Rocap Number(s):
Heat Number(s): 5393947
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: a325
Bolt Length(s): 4 1/4
Nut Specification: n/a
Washer Specification: n/a
Finish: hdg
Diameter/Size: 1 1/2"
Bolt Mfg. Lot Number: 5393947
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2022-04-06-2-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Pitch Diameter
|
1.401 in
|
Pitch Diameter 2nd
|
1.401 in
|
DIME Test ID: 2022-04-06-2-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Pitch Diameter
|
1.401 in
|
Pitch Diameter 2nd
|
1.401 in
|
DIME Test ID: 2022-04-06-2-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Pitch Diameter
|
1.409 in
|
Pitch Diameter 2nd
|
1.409 in
|
DIME Test ID: 2022-04-06-2-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
2.12 mils
|
DIME Test ID: 2022-04-06-2-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
2.16 mils
|
DIME Test ID: 2022-04-06-2-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
2.24 mils
|
DIME Test ID: 2022-04-06-2-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
25.05
|
Spacing
|
Ok
|
DIME Test ID: 2022-04-06-2-8
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/17/2022
Date Tested: 05/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
103394
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
FF A325
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
26.63
|
Spacing
|
Ok
|