Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215518 DEA: 074W7704 EFIS: 0719000274
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60-R0.6/R29.4
Work Description: METHATCRYLATE DECK, REPLACE JOINT SEAL, POLYESTER CONCRETE OVERLAY.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM ROUTE 60/5 SEPARATION TO GAREY AVENUE UNDERCROSSING
Contractor Name: VELARDE CONCRETE CONSTRUCTION INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-03-22-19
TL Number from the TL Form: JD22010
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/22/2022
Date that the sample was received by the laboratory/organization performing the testing: 04/01/2022
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4" HMA-A 105793 AAA-Irwindale
From where was the sample collected: Manufacturer
Laboratory sample identification: 22-0090
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Irwindale
DIME Test ID: 2022-03-22-19-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/05/2022
Date Tested: 04/04/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7359.3 grams
|
Mass of oven-dry sample in air for Sample 1
|
2541.2 grams
|
Mass of container filled with the sample and water for Sample 1
|
8885.5 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.504
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2022-03-22-19-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/05/2022
Date Tested: 04/04/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
no data
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
Mass of HMA Sample prior to ignition
|
2041.8 g
|
Corrected Asphalt Binder Content
|
4.60 %
|
Mass Loss
|
no data
|
Mass of aggregate remaining after ignition
|
1940.3 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.37 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000.4 F
|