Print Report | Back to Sample Detail

Sample Record for 2022-03-18-42

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214819 DEA: 07288304 EFIS: 0700021024 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60,60,164,210-Var
Work Description: STORM WATER MITIGATION
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS
Contractor Name: CHUMO CONSTRUCTION INC
Contractor Address: 14425 Joanbridge St, Baldwin Park, CA 91706
Resident Engineer: Sushilkumar Chaudhari Structure Rep.: Pratheep Piratheepan

Sample Information

DIME Sample ID: 2022-03-18-42
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 03/18/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/22/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0178-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Irwindale

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2022-03-18-42-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 03/30/2022
Date Tested: 03/23/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 60 C
Softening Point Sample 2 60 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2022-03-18-42-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 03/30/2022
Date Tested: 03/24/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Block Penetration
Block Penetration 24 0.1 mm
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2022-03-18-42-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 03/30/2022
Date Tested: 03/24/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 75 mm
Ball Penetration (P1) 3 mm
Final Dial reading (F2) 74 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F3) 74 mm
Ball Penetration (P3) 1 mm
Resilience 1 28 %
Resilience 2 27 %
Resilience 3 27 %
Average Resilience 27 %
Minutes Reaction no data