Print Report | Back to Sample Detail

Sample Record for 2022-03-07-18

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-03-07-18
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/07/2022
The quantity of what the sample constitutes: 24 boxes
A brief description of the sample: 1/2" HMA WMA PG 64-10 with 25% RAP
From where was the sample collected: Supplier
Laboratory sample identification: 022-007
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2022-03-07-18-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/12/2022
Date Tested: 04/12/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 2
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Method Performed Mechanical Agitation - Method A
Mass of oven-dry sample in air for Sample 1 1706.6 grams
Mass of sample in water for Sample 1 1026.0 grams
Mass of oven-dry sample in air for Sample 2 1607.0 grams
Mass of sample in water for Sample 2 964.9 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.507
Specific Gravity for Sample 2 2.503
Average Specific Gravity 2.505
Theoretical maximum density at 25°C (77°F) no data

Test 2 of 4

DIME Test ID: 2022-03-07-18-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 04/12/2022
Date Tested: 04/12/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.7 %
Percent Air Voids 2 4.0
Percent Air Voids 3 3.7
Percent Air Voids Average 3.8

Test 3 of 4

DIME Test ID: 2022-03-07-18-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/12/2022
Date Tested: 04/12/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.411
Bulk Specific Gravity 2 2.404
Bulk Specific Gravity 3 2.414
Average Bulk Specific Gravity 2.41

Test 4 of 4

DIME Test ID: 2022-03-07-18-10
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
Data has not been verified.

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2022-03-07-18-6AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)03/27/2022Not scheduledGlenn BradleyCT HQ - Sacramento Hot Mix Asphalt LaboratoryGlenn Bradley
2022-03-07-18-7AASHTO T312-14: Preparing and Determining the Density of Asphalt Mixture Specimens by Means of the Superpave Gyratory Compactor (Method of Compaction)03/27/2022Not scheduledGlenn BradleyCT HQ - Sacramento Hot Mix Asphalt LaboratoryGlenn Bradley
2022-03-07-18-8AASHTO T329-13: Standard Method of Test for Moisture Content of Asphalt Mixtures by Oven Method (Moisture Content)03/27/2022Not scheduledGlenn BradleyCT HQ - Sacramento Hot Mix Asphalt LaboratoryGlenn Bradley
2022-03-07-18-9CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt03/27/2022Not scheduledGlenn BradleyCT HQ - Sacramento Hot Mix Asphalt LaboratoryGlenn Bradley