Sample Record for 2022-03-01-40

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215697 DEA: 07318204 EFIS: 0715000286 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-Route 1-4.0/4.2
Work Description: CM/GC Project - Work consists of constructing secant wall and slope restoration
Location Description: near Point Mugu State Park 0.4 mile South of Sycamore Canyon Road.
Contractor Name: Flatiron/Drill Tech, a Joint Venture
Contractor Address: 15335 Fairfield Ranch Rd, Chino Hills, CA 91709
Resident Engineer: Saeid Shakeri Structure Rep.: Azizollah Maghsoudloo

Sample Information

DIME Sample ID: 2022-03-01-40
TL Number from the TL Form: 053550
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Preliminary
Type of Material: Concrete
Sample Taken Date: 03/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/03/2022
The quantity of what the sample constitutes: 10 cubic yards
A brief description of the sample: PCC cylinder trial batch SL4K475WHU
From where was the sample collected: Source
Laboratory sample identification: 22-0051
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Associate Ready Mix

Material Information

The concrete mix design number: SL4K475WHU
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: Associated Ready Mix
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CHUTE FROM TRUCK
Where the material sample would have been placed if not sampled: NA
From Lot No.: NA
Bag Lot No.: NA

Test Results

Test 1 of 2

DIME Test ID: 2022-03-01-40-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/15/2022
Date Tested: 03/15/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 7040 psi
Maximum load on cylinder 1 198771 lb
Maximum load on cylinder 2 197812 lb
Compressive strength of cylinder 1 7053.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 7019.6 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours 0 hours

Test 2 of 2

DIME Test ID: 2022-03-01-40-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/29/2022
Date Tested: 03/29/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 7920 psi
Maximum load on cylinder 1 223819 lb
Maximum load on cylinder 2 224911 lb
Compressive strength of cylinder 1 7889.3 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 7955.8 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours 0 hours