Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-03-11-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Verification
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 03/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/14/2022
The quantity of what the sample constitutes: AD Audit
A brief description of the sample: 1.5" A775 Dowels
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: American Highway
Dowel Metal Heat Number: 1201040344
Dowel Epoxy Batch Number: 3CH2122038
Dowel Coating Specification: ASTM A775
Dowel Size: 1.5 in
Dowel Coating Color: Green
Dowel Manufacturer: American Highway
Dowel Coater: American Highway
Release Number: AD Audit
Quality Assurance Code:
Rebar Size (#):
DIME Test ID: 2022-03-11-4-1
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 03/24/2022
Date Tested: 03/22/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
3
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
DIME Test ID: 2022-03-11-4-2
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 03/24/2022
Date Tested: 03/22/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
10.48 mils
|
Second Bar Mean
|
13.77 mils
|
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
40 mils
|
Total mean value
|
12.12 mils
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|