Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-03-01-17
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Authorization
Type of Material: Cementitious
Sample Taken Date: 03/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/01/2022
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: CCRL Blended cement
From where was the sample collected: Source
Laboratory sample identification: CM228089
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL Blended Cement
DIME Test ID: 2022-03-01-17-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 04/14/2022
Date Tested: 04/07/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
3 days
|
The amount of flow
|
116 %
|
The amount of water used
|
49.4 %
|
Compressive strength of 1st specimen
|
3408 psi
|
Compressive strength of 2nd specimen
|
3386 psi
|
Compressive strength of 3rd specimen
|
3409 psi
|
Average Compressive strength (to nearest 10 psi)
|
3400 psi
|
DIME Test ID: 2022-03-01-17-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 04/14/2022
Date Tested: 04/11/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
7 days
|
The amount of flow
|
116 %
|
The amount of water used
|
49.4 %
|
Compressive strength of 1st specimen
|
4463 psi
|
Compressive strength of 2nd specimen
|
4704 psi
|
Compressive strength of 3rd specimen
|
4609 psi
|
Average Compressive strength (to nearest 10 psi)
|
4590 psi
|
DIME Test ID: 2022-03-01-17-4
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 04/14/2022
Date Tested: 04/11/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
28 days
|
The amount of flow
|
114 %
|
The amount of water used
|
49.4 %
|
Compressive strength of 1st specimen
|
6435 psi
|
Compressive strength of 2nd specimen
|
6664 psi
|
Compressive strength of 3rd specimen
|
6430 psi
|
Average Compressive strength (to nearest 10 psi)
|
6510 psi
|
DIME Test ID: 2022-03-01-17-5
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 04/14/2022
Date Tested: 03/28/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity
|
3.154
|
Water Content
|
240
|
The amount of flow (In percent)
|
87 %
|
The amount of water used (In percent)
|
68.57 %
|
Net Weight of Sample
|
835.1 grams
|
Air Content
|
8 %
|
DIME Test ID: 2022-03-01-17-6
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 04/14/2022
Date Tested: 04/05/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Type IV grade reagent water
|
Initial time of setting
|
132 min
|
Final time of setting
|
240 min
|
DIME Test ID: 2022-03-01-17-7
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 04/14/2022
Date Tested: 03/28/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used
|
Test Method A
|
Test Time
|
146 seconds
|
Fineness
|
4781 cm^2/g
|
DIME Test ID: 2022-03-01-17-8
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 04/14/2022
Date Tested: 03/30/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Corrected residue, % (Rc)
|
2.8 %
|
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325)
|
97.2 %
|
DIME Test ID: 2022-03-01-17-9
Test Method: ASTM C188-15: Standard Test Method for Density of Hydraulic Cement
Verified Date: 04/14/2022
Date Tested: 04/01/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density of hydraulic cement
|
3.154 g/cm^3
|
DIME Test ID: 2022-03-01-17-10
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Verified Date: 04/14/2022
Date Tested: 04/05/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mass of Water
|
175 g
|
Mass of Dry Cement
|
650 g
|
Water required for normal consistency
|
27.0 %
|
DIME Test ID: 2022-03-01-17-11
Test Method: ASTM C151-15: Standard Test Method for Autoclave Expansion of Hydraulic Cement
Verified Date: 04/14/2022
Date Tested: 04/06/2022
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial length of specimen
|
0.1628
|
Final length of specimen
|
0.1645
|
Change in length of specimen(In percent)
|
0.02 %
|
Gauge Length
|
10
|