Sample Record for 2022-03-02-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993184 DEA: 040A7724 EFIS: 0420000288 COOP: 042763
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-80-6.4/6.8
Work Description: Excavation, HMA, structural concrete, minor concrete and drainage.
Location Description: IN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD
Contractor Name: OC Jones (Will Dieterich)
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Maxime Dabilly Structure Rep.: Eric Urementa
Sample Information
DIME Sample ID: 2022-03-02-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 03/02/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/24/2022
The quantity of what the sample constitutes: 4 hoops from lot 1 & 2
A brief description of the sample: #6's 2'-6" Ultimate welded hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 3500022833
Hoop Manufacturer Lot Number(s): Lot 1,2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 2'-6"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor
Welding Company: California Department of Transportation
Coating Standards: Uncoated
Weld Type: Flash Welded
Test Results
Test 1 of 3
DIME Test ID: 2022-03-02-3-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 03/24/2022
Date Tested: 03/24/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 1 | 1 | 6/19mm | 0.44 | 43984.44 | 99965 | ok necking | bewing |
| |
UTM
|
400kip
|
Temperature
|
72 f
|
Test 2 of 3
DIME Test ID: 2022-03-02-3-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 03/24/2022
Date Tested: 03/24/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 2 | 1 | 6/19mm | 0.44 | 44386.70 | 100879 | ok necking | bewing |
| |
UTM
|
400kip
|
Temperature
|
72 f
|
Test 3 of 3
DIME Test ID: 2022-03-02-3-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 03/24/2022
Date Tested: 03/24/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 3 | 1 | 6/19mm | 0.44 | 44352.85 | 100802 | ok necking | bewing |
| |
UTM
|
400kip
|
Temperature
|
72 f
|