Print Report | Back to Sample Detail

Sample Record for 2022-03-01-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215257 DEA: 11056374 EFIS: 1117000087 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-11-0.6/2.7
Work Description: CONSTRUCT INTERCHANGE, PLACE JPCP, HMA, AND INSTALL LIGHTING.
Location Description: SAN DIEGO COUNTY NEAR SAN DIEGO FROM 0.2 MILE WEST OF SANYO AVENUE UNDERCROSSING TO 1.2 MILE EAST OF ENRICO FERMI DRIVE OVERCROSSING
Contractor Name: SKANSKA USA CIVIL WEST CALIFORNIA DISTRICT INC.
Contractor Address: 1995 Agua Mansa Rd, Riverside, CA 92509
Resident Engineer: Victor Cardenas Structure Rep.: Wade Durant

Sample Information

DIME Sample ID: 2022-03-01-5
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 688-1570
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/01/2022
The quantity of what the sample constitutes: 3 bags, 12 boxes, 3 cans
A brief description of the sample: 3/4" HMA PSU
From where was the sample collected: Source
Laboratory sample identification: 4136-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCA Lakeside

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2022-03-01-5-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 03/03/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: 4136-JMF 11-056374 2022-03-01-5-1
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of the specimen basket assembly no data
Mass of the specimen and specimen basket assembly prior to ignition no data
Mass of HMA Sample prior to ignition 2093 g
Corrected Asphalt Binder Content 4.75 %
Mass Loss no data
Mass of aggregate remaining after ignition 1989.1 g
Correction Factor (Percent by mass of HMA Specimen) 0.21 %
Moisture Content no data0 %
Temperature Compensation Factor no data
Test Temperature 538 F

Test 2 of 7

DIME Test ID: 2022-03-01-5-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 03/02/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: 4136-JMF 056374 2022-03-01-5-2
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7361.6 grams
Mass of oven-dry sample in air for Sample 1 2559.7 grams
Mass of container filled with the sample and water for Sample 1 8882.1 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.463
Theoretical maximum density at 25°C (77°F) no data

Test 3 of 7

DIME Test ID: 2022-03-01-5-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 03/03/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: 4136-PSU 11-056374 2022-03-01-5-3
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity 2.377
Bulk Specific Gravity 2 2.377
Bulk Specific Gravity 3 2.379
Average Bulk Specific Gravity 2.378

Test 4 of 7

DIME Test ID: 2022-03-01-5-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/29/2024
Date Tested: 03/03/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: 4136-PSU 2022-03-01-5-4 11-056374
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.5 %
Percent Air Voids 2 3.5
Percent Air Voids 3 3.4
Average Percent Air Voids 3.5

Test 5 of 7

DIME Test ID: 2022-03-01-5-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/29/2024
Date Tested: 03/08/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: 4136-PSU 056374 2022-03-01-5-5
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 62 psi
Average Wet Tensile Strength 45 psi
Tensile Strength Ratio 0.73

Test 6 of 7

DIME Test ID: 2022-03-01-5-7
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 03/02/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: RAP Rice Test 0523-PSU 11-2T2184
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed no data
Mass of container filled with water 7477.4 grams
Mass of oven-dry sample in air for Sample 1 1535.9 grams
Mass of container filled with the sample and water for Sample 1 8400 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.504
Theoretical maximum density at 25°C (77°F) no data

Test 7 of 7

DIME Test ID: 2022-03-01-5-8
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 03/02/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: RAP Oil Content, Test 3 Samples. 11-056374 4136-PSU
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 4.75 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.21 %
Moisture Content no data
Temperature Compensation Factor no data