Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-02-21-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Department Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 02/23/2022
The quantity of what the sample constitutes: 195 142
A brief description of the sample: 1" x 5" a325 hdg
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: QFC
Rocap Number(s): 021022-2, 021022-3
Heat Number(s): 10700930
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: a325
Bolt Length(s): 5"
Nut Specification: na
Washer Specification: na
Finish: hdg
Diameter/Size: 1"
Bolt Mfg. Lot Number: L104U1 L913U1
Rocap Test Requirement(s): yes
Lubricant Requirements(s): yes
DIME Test ID: 2022-02-21-5-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 03/02/2022
Date Tested: 02/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | L104U1 | 1.0000 | 89354 | 397.47 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2022-02-21-5-2
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/02/2022
Date Tested: 02/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L104U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-02-21-5-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/02/2022
Date Tested: 02/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L104U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-02-21-5-4
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/02/2022
Date Tested: 02/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L104U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-02-21-5-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2022
Date Tested: 02/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L104U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Measurement Average
|
2.88 mils
|
DIME Test ID: 2022-02-21-5-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2022
Date Tested: 02/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L104U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Measurement Average
|
3.14 mils
|
DIME Test ID: 2022-02-21-5-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2022
Date Tested: 02/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L104U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Measurement Average
|
3.18 mils
|
DIME Test ID: 2022-02-21-5-8
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 03/02/2022
Date Tested: 02/28/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 2A | L913U1 | 1.0000 | 91166 | 405.52 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2022-02-21-5-9
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/02/2022
Date Tested: 02/28/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L913U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-02-21-5-10
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/02/2022
Date Tested: 02/28/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L913U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-02-21-5-11
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/02/2022
Date Tested: 02/28/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L913U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-02-21-5-12
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2022
Date Tested: 02/28/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L913U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Measurement Average
|
3.85 mils
|
DIME Test ID: 2022-02-21-5-13
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2022
Date Tested: 02/28/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L913U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Measurement Average
|
3.77 mils
|
DIME Test ID: 2022-02-21-5-14
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2022
Date Tested: 02/28/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L913U1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
1 in
|
Bolt Length
|
5 in
|
Measurement Average
|
2.97 mils
|