Print Report | Back to Sample Detail

Sample Record for 2022-02-21-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101-0.0/21.8
Work Description: San Mateo US 101 Express Lanes North
Location Description:
Contractor Name: KIEWIT INFRASTRUCTURE COMPANY
Contractor Address: 1301 SHOREWAY RD, SUITE 275, BELMONT, CA 94402
Resident Engineer: Douglas Inori Structure Rep.: Tyler Pinell

Sample Information

DIME Sample ID: 2022-02-21-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 02/25/2022
The quantity of what the sample constitutes: 14
A brief description of the sample: A325 HH Bolt w/washer and Nut
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Structural and Steel Products

Material Information

Rocap Number(s):
Heat Number(s): NF15102813
Nut Mfg. Lot Number(s): 435651A
Washer Mfg. Lot Number(s): D6010
Bolt Specification: A325
Bolt Length(s): 2-3/4
Nut Specification: A563
Washer Specification: F436
Finish: MG
Diameter/Size: 3/4 x 2-3/4
Bolt Mfg. Lot Number: 368638A
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 8

DIME Test ID: 2022-02-21-1-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 03/14/2022
Date Tested: 03/08/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1A435651A52806Nut Proof Loadspaine
UTM 450kip
Temperature 72 f

Test 2 of 8

DIME Test ID: 2022-02-21-1-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 03/14/2022
Date Tested: 03/08/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A368638A0.750050000222.4110.00A325 Wedge Tensilespaine
UTM 450kip
Temperature no data

Test 3 of 8

DIME Test ID: 2022-02-21-1-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/14/2022
Date Tested: 03/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 368638A
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 N
Size .75 in
Bolt Length 2.75 in
Gage Type Pass

Test 4 of 8

DIME Test ID: 2022-02-21-1-4
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/14/2022
Date Tested: 03/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 435651A
Finish Coating ASTM B695 - Mech Galv
Product Markings DH N
Size .75 in
Gage Type NA

Test 5 of 8

DIME Test ID: 2022-02-21-1-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/14/2022
Date Tested: 03/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 368638A
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 N
Size .75 in
Bolt Length 2.75 in
Measurement Average 2.18 mils

Test 6 of 8

DIME Test ID: 2022-02-21-1-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/14/2022
Date Tested: 03/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 435651A
Finish Coating ASTM B695 - Mech Galv
Product Markings DH N
Size .75 in
Bolt Length no data in
Measurement Average 2.21 mils

Test 7 of 8

DIME Test ID: 2022-02-21-1-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/14/2022
Date Tested: 03/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number D6010
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Measurement Average 2.23 mils

Test 8 of 8

DIME Test ID: 2022-02-21-1-8
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/14/2022
Date Tested: 03/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number D6010
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 40.9
Spacing Ok