Sample Record for 2022-02-14-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214579 DEA: 010B0904 EFIS: 0100020444
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-8.2/8.7
Work Description: Panther Creek & Hunter Creek Bridges
Location Description: DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Contractor Name: Golden State Bridge, Inc
Contractor Address: 3701 Mallard Dr., Benicia, CA 94510
Resident Engineer: Ryan Dunne Structure Rep.: Brian Cinkutis
Sample Information
DIME Sample ID: 2022-02-14-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 02/16/2022
The quantity of what the sample constitutes: 60
A brief description of the sample: ASTM F-A325 Fastener
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name: Gilman Street Pedestrian Bridge
The fabricator/manufacturer/facility name: Fontana Gruppo
Material Information
Rocap Number(s): L1414679
Heat Number(s): 10565200
Nut Mfg. Lot Number(s): 34998-212315
Washer Mfg. Lot Number(s): 0721-878
Bolt Specification: ASTM F3125-A325
Bolt Length(s): 1-1/2"
Nut Specification: A563-DH
Washer Specification: F436-1
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: L973MI
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 20
DIME Test ID: 2022-02-14-2-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | L973M1 | | 53095 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
Test 2 of 20
DIME Test ID: 2022-02-14-2-2
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Gage Type
|
Pass
|
Test 3 of 20
DIME Test ID: 2022-02-14-2-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Gage Type
|
Pass
|
Test 4 of 20
DIME Test ID: 2022-02-14-2-4
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Gage Type
|
Pass
|
Test 5 of 20
DIME Test ID: 2022-02-14-2-5
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
34998-212315
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Gage Type
|
Pass
|
Test 6 of 20
DIME Test ID: 2022-02-14-2-6
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
34998-212315
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Gage Type
|
Pass
|
Test 7 of 20
DIME Test ID: 2022-02-14-2-7
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
34998-212315
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Gage Type
|
Pass
|
Test 8 of 20
DIME Test ID: 2022-02-14-2-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Measurement Average
|
3.01 mils
|
Test 9 of 20
DIME Test ID: 2022-02-14-2-9
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Measurement Average
|
3.04 mils
|
Test 10 of 20
DIME Test ID: 2022-02-14-2-10
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Measurement Average
|
3.21 mils
|
Test 11 of 20
DIME Test ID: 2022-02-14-2-11
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
34998-212315
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.77 mils
|
Test 12 of 20
DIME Test ID: 2022-02-14-2-12
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
34998-212315
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.73 mils
|
Test 13 of 20
DIME Test ID: 2022-02-14-2-13
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
34998-212315
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.08 mils
|
Test 14 of 20
DIME Test ID: 2022-02-14-2-14
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0721-878
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.39 mils
|
Test 15 of 20
DIME Test ID: 2022-02-14-2-15
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0721-878
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.9 mils
|
Test 16 of 20
DIME Test ID: 2022-02-14-2-16
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0721-878
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.85 mils
|
Test 17 of 20
DIME Test ID: 2022-02-14-2-17
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
31.12
|
Spacing
|
Ok
|
Test 18 of 20
DIME Test ID: 2022-02-14-2-18
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L973M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA LE
|
Size
|
.75 in
|
Bolt Length
|
1.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
30.9
|
Spacing
|
Ok
|
Test 19 of 20
DIME Test ID: 2022-02-14-2-19
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0721-878
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.4
|
Spacing
|
Ok
|
Test 20 of 20
DIME Test ID: 2022-02-14-2-20
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 02/23/2022
Date Tested: 02/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0721-878
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.5
|
Spacing
|