Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214663 DEA: 081F7304 EFIS: 0815000034
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-215-2.7
Work Description: REPLACE CONCRETE BRIDGE, PLACE CONCRETE PCPS GIRDERS AND HMA.
Location Description: SAN BERNARDINO COUNTY IN COLTON AT WASHINGTON STREET OVERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVE, SYLMAR, CA, 91342
Resident Engineer: Shaine Shahidi Structure Rep.: Unknown
DIME Sample ID: 2022-01-28-22
TL Number from the TL Form:
Sample Submitted By Organization: Coreslab
Sample Organization Contact: (909) 936-7741
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/28/2022
Date that the sample was received by the laboratory/organization performing the testing: 01/29/2022
The quantity of what the sample constitutes: 28 cy
A brief description of the sample: Concrete
From where was the sample collected: Fabricator
Laboratory sample identification: 016
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coreslab Structures L.A., Inc.
The concrete mix design number: 212
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 82507-82508
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Front Discharge RMT at Bed 9
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-01-28-22-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 02/07/2022
Date Tested: 01/28/2022
Submitted By Organization: Coreslab
Organization Address: 150 West Placentia Avenue,
Organization City: Perris
Organization State: CA
Organization Zipcode: 92571
Organization Email: bmalott@coreslab.com
Organization Phone: (909) 936-7741
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-01-28-22-2
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 02/07/2022
Date Tested: 01/28/2022
Submitted By Organization: Coreslab
Organization Address: 150 West Placentia Avenue,
Organization City: Perris
Organization State: CA
Organization Zipcode: 92571
Organization Email: bmalott@coreslab.com
Organization Phone: (909) 936-7741
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample
|
212
|
Volume of the measure
|
0.249 ft^3
|
Density of concrete
|
149.8 lb/ft^3
|
Yield of concrete
|
no data
|
Relative yield of the batch
|
no data
|
Cement content
|
no data
|
Air content
|
no data
|
DIME Test ID: 2022-01-28-22-3
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 02/07/2022
Date Tested: 01/28/2022
Submitted By Organization: Coreslab
Organization Address: 150 West Placentia Avenue,
Organization City: Perris
Organization State: CA
Organization Zipcode: 92571
Organization Email: bmalott@coreslab.com
Organization Phone: (909) 936-7741
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-01-28-22-4
Test Method: ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 02/07/2022
Date Tested: 01/28/2022
Submitted By Organization: Coreslab
Organization Address: 150 West Placentia Avenue,
Organization City: Perris
Organization State: CA
Organization Zipcode: 92571
Organization Email: bmalott@coreslab.com
Organization Phone: (909) 936-7741
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-01-28-22-5
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/07/2022
Date Tested: 01/29/2022
Submitted By Organization: Coreslab
Organization Address: 150 West Placentia Avenue,
Organization City: Perris
Organization State: CA
Organization Zipcode: 92571
Organization Email: bmalott@coreslab.com
Organization Phone: (909) 936-7741
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Cross sectional area of cylinder 1
|
28.2 in^2
|
Cross sectional area of cylinder 2
|
28.2 in^2
|
Compressive strength (to nearest 10 psi)
|
5110 psi
|
Maximum load on cylinder 1
|
146358 lb
|
Maximum load on cylinder 2
|
141564 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
0 days
|
Age of specimen in hours
|
17 hours
|
DIME Test ID: 2022-01-28-22-6
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/10/2022
Date Tested: 02/08/2022
Submitted By Organization: Coreslab
Organization Address: 150 West Placentia Avenue,
Organization City: Perris
Organization State: CA
Organization Zipcode: 92571
Organization Email: bmalott@coreslab.com
Organization Phone: (909) 936-7741
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Cross sectional area of cylinder 1
|
28.2 in^2
|
Cross sectional area of cylinder 2
|
28.2 in^2
|
Compressive strength (to nearest 10 psi)
|
8680 psi
|
Maximum load on cylinder 1
|
239136 lb
|
Maximum load on cylinder 2
|
250134 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
11 days
|
Age of specimen in hours
|
0 hours
|
DIME Test ID: 2022-01-28-22-7
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/14/2022
Date Tested: 02/11/2022
Submitted By Organization: Coreslab
Organization Address: 150 West Placentia Avenue,
Organization City: Perris
Organization State: CA
Organization Zipcode: 92571
Organization Email: bmalott@coreslab.com
Organization Phone: (909) 936-7741
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Cross sectional area of cylinder 1
|
28.2 in^2
|
Cross sectional area of cylinder 2
|
28.2 in^2
|
Compressive strength (to nearest 10 psi)
|
8970 psi
|
Maximum load on cylinder 1
|
258030 lb
|
Maximum load on cylinder 2
|
247878 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
14 days
|
Age of specimen in hours
|
0 hours
|