DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030H4604 Cty PLA Rte 80 PM 2.6/3.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Justin Kunert |
Date Reported: |
03/03/2022 |
|
Address: |
TL Number: |
204471 |
||
City: |
||||
Project Name: WIDEN ON-RAMP AND REPLACE BRIDGE. |
||||
Prime Contractor: Myers & Sons Construction |
||||
Sample Taken Date: |
02/03/2022 |
Mix Design: |
T71A5D1 |
|
Contractor: Unknown |
Location : PLACER COUNTY IN ROSEVILLE AT THE ATLANTIC STREET ON RAMP |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.04 | 12.82 | 41479 | 3236.0 | 1 |
2 | 4.04 | 12.82 | 41596 | 3245.0 | 1 |
3 | 4.03 | 12.76 | 41718 | 3271 | 1 |
DIME Test ID: 2022-02-03-14-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3250
Age of specimen: 5 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.05 | 12.88 | 68548 | 5321.0 | 1 |
2 | 4.04 | 12.82 | 72358 | 5645.0 | 1 |
3 | 4.03 | 12.76 | 69343 | 5436 | 1 |
DIME Test ID: 2022-02-03-14-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5470
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing