The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.18 | 5.99 | 4376.7 | 123335 | 1 |
2 | 28.27 | 6.00 | 4993.5 | 141165 | 2 |
DIME Test ID: 2014-10-29-4-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4690
Age of specimen: 28 days