Print Report | Back to Sample Detail

Sample Record for 2022-01-19-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213747 DEA: 080Q9104 EFIS: 0800020580 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-R23.8
Work Description: RETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY.
Location Description: SAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606-4414
Resident Engineer: Roberto Castro Structure Rep.: Ching Chuang

Sample Information

DIME Sample ID: 2022-01-19-6
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 01/19/2022
Date that the sample was received by the laboratory/organization performing the testing: 01/19/2022
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt

Material Information

Mfg. Lot Number(s): 1383317
Batch number: 1383317
Mix number: 1383317

Test Results

Test 1 of 6

DIME Test ID: 2022-01-19-6-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 03/15/2022
Date Tested: 01/28/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 115

Test 2 of 6

DIME Test ID: 2022-01-19-6-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 03/15/2022
Date Tested: 01/28/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 3 of 6

DIME Test ID: 2022-01-19-6-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 03/15/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accept supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.485 in
Sample 1 Ultimate strength 3671.9 psi
Sample 1 Thickness 0.25 in
Sample 1 Area 0.1213 in^2
Sample 1 Ultimate Strength Actual 445.4 lbs
Sample 1 percent elongation 43.28 %
Sample 1 Time 0 MM:SS
Sample 2 Width 0.484 in
Sample 2 Thickness 0.252 in
Sample 2 Area 0.122 in^2
Sample 2 Ultimate strength 3623.8 psi
Sample 2 Ultimate Strength Actual 442.1 lbs
Sample 2 percent elongation 61.56 %
Sample 2 Time 0 MM:SS
Sample 3 Width 0.484 in
Sample 3 Thickness 0.245 in
Sample 3 Area 0.1186 in^2
Sample 3 Ultimate strength 3586.8 psi
Sample 3 Ultimate Strength Actual 425.4 lbs
Sample 3 percent elongation 64.49 %
Sample 3 Time 0 MM:SS
Sample 4 Width 0.483 in
Sample 4 Thickness 0.248 in
Sample 4 Area 0.1198 in^2
Sample 4 Ultimate strength 3551.8 psi
Sample 4 Ultimate Strength Actual 425.5 lbs
Sample 4 percent elongation 57.99 %
Sample 4 Time 0 MM:SS
Sample 5 Width 0.484 in
Sample 5 Thickness 0.243 in
Sample 5 Area 0.1176 in^2
Sample 5 Ultimate strength 3539.1 psi
Sample 5 Ultimate Strength Actual 416.2 lbs
Sample 5 percent elongation 49.94 %
Sample 5 Time 0 MM:SS
Sample 6 Width 0.484 in
Sample 6 Thickness 0.248 in
Sample 6 Area 0.12 in^2
Sample 6 Ultimate strength 3555 psi
Sample 6 Ultimate Strength Actual 426.6 lbs
Sample 6 percent elongation 51.83 %
Sample 6 Time 0 MM:SS
Ultimate Strength Average 3588 psi
Percent Elongation Average 55 %

Test 4 of 6

DIME Test ID: 2022-01-19-6-5
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 03/15/2022
Date Tested: 01/28/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 45

Test 5 of 6

DIME Test ID: 2022-01-19-6-6
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 03/15/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accept supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1447.8 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 723.9 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1699.4 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 849.7 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1559.6 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 779.8 psi

Test 6 of 6

DIME Test ID: 2022-01-19-6-7
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 03/15/2022
Date Tested: 01/19/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accept supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 75 f
Tare weight 0 grams
Initial weight 100 grams
Weight at 5 minutes 99.948 grams
Weight at 10 minutes 99.895 grams
Weight at 15 minutes 99.843 grams
Weight at 20 minutes 99.791 grams
Weight at 25 minutes 99.737 grams
Weight at 30 minutes 99.683 grams
Final weight 99.68 grams
Total weight loss 0.32 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 17.202 grams/m^2