Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-01-10-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 01/10/2022
Date that the sample was received by the laboratory/organization performing the testing: 01/10/2022
The quantity of what the sample constitutes: 21
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number: 10987
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0558421, S0558021, S0557921, S0557821
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire
DIME Test ID: 2022-01-10-12-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0558421 | S335990-3 | 0.218 | 60714 | 56149.2 | 28.7 | 1.97 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
DIME Test ID: 2022-01-10-12-2
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0558421 | S335990-4 | 0.218 | 60544 | 57948.3 | 46.1 | 1.74 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
DIME Test ID: 2022-01-10-12-3
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0558021 | S335991-3 | 0.218 | 60121 | 55960.0 | 29.5 | 1.85 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
DIME Test ID: 2022-01-10-12-4
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0558021 | S335991-5 | 0.218 | 60508 | 55303.6 | 29 | 1.94 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
DIME Test ID: 2022-01-10-12-5
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0557921 | S335992-4 | 0.218 | 60570 | 55839.7 | 29.3 | 1.92 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
DIME Test ID: 2022-01-10-12-6
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0557921 | S335992-6 | 0.218 | 60565 | 55108.1 | 28.5 | 1.96 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
DIME Test ID: 2022-01-10-12-7
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0557821 | S335994-1 | 0.216 | 59881 | 55525.1 | 29.1 | 1.83 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|
DIME Test ID: 2022-01-10-12-8
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/20/2022
Date Tested: 01/20/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0557821 | S335994-4 | 0.216 | 60010 | 54365.9 | 28.5 | 1.93 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
E88768
|