Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 051K7004 Cty MON Rte 1 PM 64.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Arashdeep (Art) Pannu |
Date Reported: |
03/17/2022 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: TREAT EXISTING STRUCTURE WITH ELECTROCHEMICAL CHLORIDE EXTRACTION. |
||||
Prime Contractor: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC |
||||
Sample Taken Date: |
01/04/2022 |
Mix Design: |
SikaTop 123 |
|
Contractor: Unknown |
Location: MONTEREY COUNTY NEAR CARMEL-BY-THE SEA AT GRANITE CANYON BRIDGE |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.04 | 12.82 | 93881 | 7324.0 | 1 |
2 | 4.03 | 12.76 | 88674 | 6952.0 | 1 |
3 | 4.04 | 12.82 | 91487 | 7137 | 1 |
DIME Test ID: 2022-01-04-9-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 7140
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C469-14: Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression (Static Modulus of Elasticity)
Specimen | Diameter specimen (in) | Length specimen (in) | Cross sectional area specimen (in^2) | Age specimen (days) | Static Modulus of Elasticity specimen (msi) |
---|---|---|---|---|---|
1 | 4 | 8 | 12.5664 | 28 | 2.35 |
2 | 4 | 8 | 12.5664 | 28 | 2.3 |
3 | 4 | 8 | 12.5664 | 28 | 2.26 |
DIME Test ID: 2022-01-04-9-2
Number of Specimens: 3
Average Static Modulus of Elasticity: 2.3033
Curing and environmental histories: Type 1 100% Humidity Room Cure
Certified By: Spencer Adams
CTM 550-December 2013: Method for Determining the Surface Abrasion Resistance of Concrete Specimens
Abrasion loss in grams |
---|
11 |
DIME Test ID: 2022-01-04-9-3
Certified By: Spencer Adams
CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Material type | Amount of the analyte in the sample |
---|---|
Concrete | 783 |
DIME Test ID: 2022-01-04-9-4
Certified By: Spencer Adams
CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Material type | Amount of the analyte in the sample |
---|---|
Concrete | 9 |
DIME Test ID: 2022-01-04-9-5
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing