Print Report | Back to Sample Detail

Sample Record for 2021-12-03-41

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212779 DEA: 021H5804 EFIS: 0216000024 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-58.4/R78.4
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mike Zdenek Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-12-03-41
TL Number from the TL Form: 876435
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Preliminary
Type of Material: Soil
Sample Taken Date: 12/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 12/06/2021
The quantity of what the sample constitutes: Existing soil at 02-PLU-70-63.1
A brief description of the sample: 1 bag of soil for use in geogrid embankment design
From where was the sample collected: Job Site
Laboratory sample identification: D78985
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 02-PLU-70-63.09 from face of slope on North side of road, 0 to 0.83 ft. depth
Where the material sample would have been placed if not sampled: In situ

Test Results

Test 1 of 4

DIME Test ID: 2021-12-03-41-1
Test Method: CTM 203-February 2008: Mechanical Analysis of Soils
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive, MS-83,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: (530) 225-3194
This test has been superseded on 01/21/2022. The corrected test ID is: 2021-12-03-41-3
Reason: retested

Test 2 of 4

DIME Test ID: 2021-12-03-41-2
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive, MS-83,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: (530) 225-3194
This test has been superseded on 01/21/2022. The corrected test ID is: 2021-12-03-41-4
Reason: retested

Test 3 of 4

DIME Test ID: 2021-12-03-41-3
Test Method: CTM 203-February 2008: Mechanical Analysis of Soils
Verified Date: 01/21/2022
Date Tested: 01/14/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
The test was superseded from test ID: 2021-12-03-41-1
Test Result Compliance:
Additional Comments When Verified:
Cumulative percent passing the 3 in. sieve 100 %
Cumulative percent passing the 2 1/2 in. sieve 100 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 99 %
Cumulative percent passing the #8 sieve 98 %
Cumulative percent passing the #16 sieve 96 %
Cumulative percent passing the #30 sieve 90 %
Cumulative percent passing the #50 sieve 79 %
Cumulative percent passing the #100 sieve 60 %
Cumulative percent passing the #200 sieve 51 %
Cumulative Percent Passing on 1 Micron 22 %
Cumulative Percent Passing on 5 Microns 32 %

Test 4 of 4

DIME Test ID: 2021-12-03-41-4
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 01/21/2022
Date Tested: 01/19/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
The test was superseded from test ID: 2021-12-03-41-2
Test Result Compliance:
Additional Comments When Verified:
Plastic Index(PI) 15
Liquid Limit (LL) 34 %
Plastic Limit (PL) 19 %