REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Martin Clark |
Date Reported: |
10/23/2014 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: IMPROVING VERTICAL CLEARANCE |
||||
Prime Contractor: RGW Construction Inc |
||||
Sample Taken Date: |
10/09/2014 |
Mix Design: |
j7a8543cc |
|
Contractor: Unknown |
Location: PLACER COUNTY IN AND NEAR LOOMIS, PENRYN, NEWCASTLE, WEIMAR, AND MAGRA FROM 0.1 MILE WEST OF BRACE ROAD OVERCROSSING TO 0.1 MILE EAST OF MAGRA OVERCROSSING |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.46 | 6.02 | 4213.1 | 119904 | 1 |
2 | 28.46 | 6.02 | 4470.1 | 127220 | 1 |
DIME Test ID: 2014-10-09-2-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4340
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 4 days
Certified By: Mike Mullins
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.46 | 6.02 | 4213.1 | 119904 | 1 |
2 | 28.46 | 6.02 | 4470.1 | 127220 | 1 |
DIME Test ID: 2014-10-09-2-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4340
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 4 days
Certified By: Steve Wake
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.56 | 6.03 | 4660.9 | 133116 | 1 |
2 | 28.46 | 6.02 | 4568.8 | 130029 | 1 |
DIME Test ID: 2014-10-09-2-3
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4610
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 5 days
Certified By: Mike Mullins
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.27 | 6.00 | 6220.8 | 175861 | 1 |
2 | 28.18 | 5.99 | 6342.9 | 178742 | 1 |
DIME Test ID: 2014-10-09-2-4
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6280
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 14 days
Certified By: Mike Mullins