Sample Record for 2019-08-15-20
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125
QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-5-R3.8/R11.7
Work Description: WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location Description: SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
Contractor Name: J.F. SHEA CONSTRUCTION
Contractor Address: P.O. BOX 494519, REDDING, CA 96049-4519
Resident Engineer: Henry Benner Structure Rep.: Eric Chaffee
Sample Information
DIME Sample ID: 2019-08-15-20
TL Number from the TL Form: 898330
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 08/15/2019
Date that the sample was received by the laboratory/organization performing the testing: 08/15/2019
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Combined Untreated 3/4-inch Type G Aggregate
From where was the sample collected: Source
Laboratory sample identification: D78105F
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JF Shea Construction - Fawndale Rock Quarry - Redding
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-45-0017
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Laboratory Batched from Sized Untreated Stockpile Samples
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: JMF 19-26-S1
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 8
DIME Test ID: 2019-08-15-20-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 12/14/2021
Date Tested: 08/27/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
HMA Gradation
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
99.4 %
|
Cumulative percent passing the 1/2 in. sieve
|
77.9 %
|
Cumulative percent passing the 3/8 in. sieve
|
63.3 %
|
Cumulative percent passing the 1/4 in. sieve
|
44.6 %
|
Cumulative percent passing the #4 sieve
|
34.5 %
|
Cumulative percent passing the #8 sieve
|
20 %
|
Cumulative percent passing the #16 sieve
|
12.1 %
|
Cumulative percent passing the #30 sieve
|
8 %
|
Cumulative percent passing the #50 sieve
|
5.7 %
|
Cumulative percent passing the #100 sieve
|
4.2 %
|
Cumulative percent passing the #200 sieve
|
3.39 %
|
Test 2 of 8
DIME Test ID: 2019-08-15-20-2
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 12/14/2021
Date Tested: 08/28/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic Index(PI)
|
NP
|
Liquid Limit (LL)
|
0 %
|
Plastic Limit (PL)
|
0 %
|
Test 3 of 8
DIME Test ID: 2019-08-15-20-3
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 12/14/2021
Date Tested: 08/29/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method
|
1 - Combined Fracture Determination
|
Aggregate Size and Fracture Type
|
Coarse 1 and 2 Faced and Fine 1 Faced
|
Percentage of questionable, coarse, 2 faced particles tested
|
0 %
|
Percentage of questionable, coarse, 1 faced particles tested
|
0 %
|
Percentage of questionable, fine, 1 faced particles tested
|
0 %
|
Percentage of fractured, coarse, 2 faced particles tested
|
100 %
|
Percentage of fractured, coarse, 1 faced particles tested
|
100 %
|
Percentage of fractured, fine, 1 faced particles tested
|
100 %
|
Test 4 of 8
DIME Test ID: 2019-08-15-20-4
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 12/14/2021
Date Tested: 08/28/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation
|
B
|
Mass of sample on No.12 sieve (after 500 revolutions)
|
4366 grams
|
Percent loss after 100 revolutions
|
3 %
|
Percent loss after 500 revolutions
|
12 %
|
Test 5 of 8
DIME Test ID: 2019-08-15-20-5
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 12/14/2021
Date Tested: 08/29/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Test 6 of 8
DIME Test ID: 2019-08-15-20-6
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 12/14/2021
Date Tested: 08/29/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Which test procedure(s) is/are used?
|
Procedure A and Procedure B
|
Was strict temperature control maintained?
|
Yes
|
What type of water was used?
|
Distilled
|
Durability Index (coarse)
|
82
|
Durability Index (fine)
|
80
|
Test 7 of 8
DIME Test ID: 2019-08-15-20-7
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 12/14/2021
Date Tested: 08/29/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed?
|
Method A
|
Bulk dry specific gravity
|
2.674
|
Average uncompacted voids
|
48.2 %
|
Test 8 of 8
DIME Test ID: 2019-08-15-20-8
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 12/14/2021
Date Tested: 08/29/2019
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method
|
B
|
Determination
|
By Mass
|
Dimensional ratio used
|
5:1
|
Weighted percentage of particles (by mass) that were flat and elongated
|
2 %
|
Weighted percentage of particles (by mass) that were not flat and elongated
|
98 %
|