Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-11-08-42
TL Number from the TL Form:
Sample Submitted By Organization: San Joaquin Refinery - Bakersfield
Sample Organization Contact: (661) 327-8248
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 11/08/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/08/2021
The quantity of what the sample constitutes: 1 of 2 cans
A brief description of the sample: PG58-16 Asphalt binder
From where was the sample collected: Manufacturer
Laboratory sample identification: 5816211108
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refinery
Performance Grade: PG 58-16
Modified: No
Lot number: 5816211108
Sublot number:
Tank number: 2002
Time of sample: 9:15am
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-11-08-42-1
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Verified Date: 12/03/2021
Date Tested: 11/08/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell Street,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: donp@sjr.com
Organization Phone: (661) 327-8248
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg)
|
Celsius and mmHg
|
Observed Flash Point
|
318 C
|
Ambient Barometric Pressure
|
755 mmHg
|
Cleveland Open-Cup Flash Point in Celsius
|
318 C
|
DIME Test ID: 2021-11-08-42-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 12/03/2021
Date Tested: 11/08/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell Street,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: donp@sjr.com
Organization Phone: (661) 327-8248
General Comments for this Test: Test @58C
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
88.9 degree
|
Dynamic Shear, G*/sin(δ)
|
1.70 kPa
|
DIME Test ID: 2021-11-08-42-3
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 12/03/2021
Date Tested: 11/08/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell Street,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: donp@sjr.com
Organization Phone: (661) 327-8248
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Average mass change
|
-0.100 percent
|
DIME Test ID: 2021-11-08-42-4
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 12/03/2021
Date Tested: 11/08/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell Street,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: donp@sjr.com
Organization Phone: (661) 327-8248
General Comments for this Test: Test @ 25C
Test Result Compliance:
Additional Comments When Verified:
Is a normal test obtainable?
|
Yes
|
Number of replicates tested
|
Two
|
Ductility of test #1 (D1)
|
150 cm
|
Ductility of test #2 (D2)
|
150 cm
|
Ductility of sample
|
150 cm
|
DIME Test ID: 2021-11-08-42-5
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 12/03/2021
Date Tested: 11/08/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell Street,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: donp@sjr.com
Organization Phone: (661) 327-8248
General Comments for this Test: Test @ 58C
Test Result Compliance:
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
87.8 degree
|
Dynamic Shear, G*/sin(δ)
|
3.10 kPa
|
DIME Test ID: 2021-11-08-42-6
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 12/03/2021
Date Tested: 11/09/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell Street,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: donp@sjr.com
Organization Phone: (661) 327-8248
General Comments for this Test: Test @ 25C
Test Result Compliance:
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Phase Angle (δ) (for the 10 cycles)
|
61.4 degree
|
(G*) x sin(δ)=
|
4321 kPa
|
DIME Test ID: 2021-11-08-42-7
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 12/03/2021
Date Tested: 11/09/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell Street,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: donp@sjr.com
Organization Phone: (661) 327-8248
General Comments for this Test: Test @ -6.0 C
Test Result Compliance:
Additional Comments When Verified:
Time test started
|
12:14:26 HH:MM:SS
|
Flags issued by software during test
|
None
|
Correlation coefficient (R²)
|
0.999994
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
0.0 mN
|
Beam deflection 60.0 s
|
0.000 µm
|
Measured Stiffness Modulus 60.0 s
|
80.700 mPa
|
Estimated Stiffness Modulus 60.0 s
|
80.700 mPa
|
Difference between stiffness moduli 60.0 s
|
0.00 %
|
Estimated m-value 60.0 s
|
0.432
|