The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 61789 | 4868.0 | 1 |
2 | 4.02 | 12.69 | 65431 | 5155.0 | 1 |
3 | 4.02 | 12.69 | 63746 | 5022 | 1 |
DIME Test ID: 2021-11-30-31-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5020
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
![]() |