Print Report | Back to Sample Detail

Sample Record for 2021-10-21-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-10-21-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Per Request
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 10/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 12/01/2021
The quantity of what the sample constitutes: 1
A brief description of the sample: bearing pad w steel plate
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DS Brown

Material Information

Mfg. Lot Number(s): C2108-5560-02
Material/Compound/Elastomer ID: na
Samples Representing: 9
Description (size): 3.45"x15"x15"
Comments:
Description (Number of Shims): 6
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): DS Brown
Batch Number: na

Test Results

Test 1 of 4

DIME Test ID: 2021-10-21-27-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 12/06/2021
Date Tested: 12/02/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 50
Reading #2 50
Reading #3 51
Reading #4 51
Reading #5 51
Mean 50.6

Test 2 of 4

DIME Test ID: 2021-10-21-27-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 12/06/2021
Date Tested: 12/02/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.082
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2749 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.083
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2818.54 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.084
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2599.25 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2749 lbf/in^2

Test 3 of 4

DIME Test ID: 2021-10-21-27-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 12/06/2021
Date Tested: 12/02/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.077
Sample 1 Tear Strength 273.7
Sample 2 Median Thickness 0.081
Sample 2 Tear Strength 256.8
Sample 3 Median Thickness 0.077
Sample 3 Tear Strength 267.5
Median of the Tear Strength Values 267.5 lb/in

Test 4 of 4

DIME Test ID: 2021-10-21-27-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 12/03/2021
Date Tested: 12/03/2021
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass