Print Report | Back to Sample Detail

Sample Record for 2021-11-02-29

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-11-02-29
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 11/02/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/05/2021
The quantity of what the sample constitutes: 8
A brief description of the sample: .5 Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number: 10984
Strand Diameter: .5 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0597421, S0597121
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Results

Test 1 of 4

DIME Test ID: 2021-11-02-29-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 11/30/2021
Date Tested: 11/19/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597421S132026-10.1534330540384.729.41.76bewing
UTM 120kip
Temperature 72 f
Extensometers E88768

Test 2 of 4

DIME Test ID: 2021-11-02-29-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 11/30/2021
Date Tested: 11/19/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597421S132026-50.1534360541635.632.41.7bewing
UTM 120kip
Temperature 72 f
Extensometers E88768

Test 3 of 4

DIME Test ID: 2021-11-02-29-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 11/30/2021
Date Tested: 11/19/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597121S132029-50.1534419140961.930.21.86bewing
UTM 120kip
Temperature 72 f
Extensometers E88768

Test 4 of 4

DIME Test ID: 2021-11-02-29-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 11/30/2021
Date Tested: 11/19/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0597121S132030-50.1534363140364.628.71.72bewing
UTM 120kip
Temperature 72 f
Extensometers E88768