Project ID: 215424 DEA: 024G4404 EFIS: 0214000013
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-3-38.0/38.6
Work Description: BRIDGE REPLACEMENT
Location Description: SISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
Contractor Name: Steelhead Constructors
Contractor Address: 2940 INNSBRUCK DRIVE, REDDING CA 96003
Resident Engineer: Nicole Mallory Structure Rep.: Andy O'Sullivan
DIME Sample ID: 2021-11-02-28
TL Number from the TL Form: 853085
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/02/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/02/2021
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 22.0% RAP and virgin PG 58-34 M from Valero - Benicia
From where was the sample collected: Manufacturer
Laboratory sample identification: D78970
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis - Northstate Asphalt - Redding, CA
DIME Test ID: 2021-11-02-28-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/19/2021
Date Tested: 11/03/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7336.5 grams
|
Mass of oven-dry sample in air for Sample 1
|
2653.2 grams
|
Mass of container filled with the sample and water for Sample 1
|
8937.9 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.523
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2021-11-02-28-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/19/2021
Date Tested: 11/02/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
no data
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
4.67 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.33 %
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|
DIME Test ID: 2021-11-02-28-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 11/19/2021
Date Tested: 11/03/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.422
|
Bulk Specific Gravity 2
|
2.416
|
Bulk Specific Gravity 3
|
2.417
|
Average Bulk Specific Gravity
|
2.418
|
DIME Test ID: 2021-11-02-28-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 11/19/2021
Date Tested: 11/03/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
4 %
|
Percent Air Voids 2
|
4.2 %
|
Percent Air Voids 3
|
4.2 %
|
Average Percent Air Voids
|
4.1 %
|
DIME Test ID: 2021-11-02-28-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 11/19/2021
Date Tested: 11/18/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
SI Units
|
Average Dry Tensile Strength
|
127 psi
|
Average Wet Tensile Strength
|
128 psi
|
Tensile Strength Ratio
|
1.01
|