Sample Record for 2021-11-08-21
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2021-11-08-21
TL Number from the TL Form:
Sample Submitted By Organization: HollyFrontier Asphalt Company LLC
Sample Organization Contact: (623) 939-3311
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 11/08/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/08/2021
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Tank 512
From where was the sample collected: Manufacturer
Laboratory sample identification: 21-245
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Glendale, AZ
Material Information
Performance Grade: PG 58-34M
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: HollyFrontier
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
Test Results
Test 1 of 5
DIME Test ID: 2021-11-08-21-1
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 11/12/2021
Date Tested: 11/12/2021
Submitted By Organization: HollyFrontier Asphalt Company LLC
Organization Address: 7110 West Northern Avenue,
Organization City: Glendale
Organization State: AZ
Organization Zipcode: 85303
Organization Email: thomas.ludlum@hollyfrontier.com
Organization Phone: (623) 939-3311
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
Time of test
|
no data HH:MM
|
Test Temperature
|
0 C
|
Speed
|
0 rpm
|
Spindle size
|
no data in
|
Torque
|
0 %
|
Viscosity reading #1 (A)
|
no data
|
Viscosity reading #2 (B)
|
no data
|
Viscosity reading #3 (C)
|
no data
|
Average viscosity
|
0.71 Pa-s
|
Test 2 of 5
DIME Test ID: 2021-11-08-21-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/12/2021
Date Tested: 11/12/2021
Submitted By Organization: HollyFrontier Asphalt Company LLC
Organization Address: 7110 West Northern Avenue,
Organization City: Glendale
Organization State: AZ
Organization Zipcode: 85303
Organization Email: thomas.ludlum@hollyfrontier.com
Organization Phone: (623) 939-3311
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
no data
|
Phase Angle (δ) (for the 10 cycles)
|
no data
|
Dynamic Shear, G*/sin(δ)
|
1.20 kPa
|
Test 3 of 5
DIME Test ID: 2021-11-08-21-3
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 11/12/2021
Date Tested: 11/12/2021
Submitted By Organization: HollyFrontier Asphalt Company LLC
Organization Address: 7110 West Northern Avenue,
Organization City: Glendale
Organization State: AZ
Organization Zipcode: 85303
Organization Email: thomas.ludlum@hollyfrontier.com
Organization Phone: (623) 939-3311
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
One
|
Average mass change
|
-0.027 percent
|
Test 4 of 5
DIME Test ID: 2021-11-08-21-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/12/2021
Date Tested: 11/12/2021
Submitted By Organization: HollyFrontier Asphalt Company LLC
Organization Address: 7110 West Northern Avenue,
Organization City: Glendale
Organization State: AZ
Organization Zipcode: 85303
Organization Email: thomas.ludlum@hollyfrontier.com
Organization Phone: (623) 939-3311
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
no data
|
Phase Angle (δ) (for the 10 cycles)
|
no data
|
Dynamic Shear, G*/sin(δ)
|
2.23 kPa
|
Test 5 of 5
DIME Test ID: 2021-11-08-21-5
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Delta at 2.2 kpa)
Submitted By Organization: HollyFrontier Asphalt Company LLC
Organization Address: 7110 West Northern Avenue,
Organization City: Glendale
Organization State: AZ
Organization Zipcode: 85303
Organization Email: thomas.ludlum@hollyfrontier.com
Organization Phone: (623) 939-3311