Print Report | Back to Sample Detail

Sample Record for 2021-10-06-41

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214756 DEA: 050N7AU4 EFIS: 0520000030 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-1.4/4.8
Work Description: Segment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location Description: CARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Rd, Santa Barbara, CA 93160
Resident Engineer: Taylor Merlo Structure Rep.: Bernardo Hernandez

Sample Information

DIME Sample ID: 2021-10-06-41
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/06/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/03/2021
The quantity of what the sample constitutes: 3 cylinders
A brief description of the sample: Class II 4000 psi 4" slump
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hanson - goleta

Material Information

The concrete mix design number: 63511N0P
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 550199
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: NB Hwy 101 Carpinteria
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2021-10-06-41-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/05/2021
Date Tested: 11/03/2021
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.01 in
Average diameter of cylinder 3 6.01 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.37 in^2
Cross sectional area of cylinder 3 28.37 in^2
Compressive strength (to nearest 10 psi) 4590 psi
Maximum load on cylinder 1 95050 lb
Maximum load on cylinder 2 130720 lb
Maximum load on cylinder 3 129960 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours 0 hours